<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22290</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Air supply filter has been permanently damaged and MUST be replace, even if this message does not re-occur
</ErrorMessage>
<ServiceInformation>
<DescriptionText><text>
This indicates filter has been blocked once and tunneling may
start to occur - Ref Mark McGair.Trendsetter_VLF_Auto
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Replace compressed air filters.  Even if this only occurs once, the filters
should be replaced, especially if they look dirty.  The filter can break down
on a microscopic level and allow particles through. (process is called tunneling)
</text></DescriptionText>
</OperatorAction>
<Cause>
Differential pressure drop across the filter is more than the dirty
filter threshold. Checked during initialize.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/ale_air.xml</LinkAddress><LinkTitle>Command: ale air</LinkTitle></Link>
<Link><LinkAddress>../nvs/val_cfg_pdi.xml</LinkAddress><LinkTitle>NVS: val pdi</LinkTitle></Link>
<Link><LinkAddress>../nvs/val_cfg_pde.xml</LinkAddress><LinkTitle>NVS: val pde</LinkTitle></Link>
<Link><LinkAddress>../nvs/val_cal_dft.xml</LinkAddress><LinkTitle>NVS: val dft</LinkTitle></Link>
<Link><LinkAddress>../nvs/val_cal_mft.xml</LinkAddress><LinkTitle>NVS: val mft</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:03 2008 PST
</Updated>
<Links>
</Links>
</Error>